COS-50 |

|
MSDS |
|||||||||
|
|
MATERIAL SAFETY DATA SHEET |
|
|||||||
|
REV. DATE 2/06/2003 |
|
|
|
|
|
|
|
||
|
QUICK IDENTIFIER: |
ROAD BUILDING CAPE OVER SEAL FOR CHIP SEAL |
|
|
|
|||||
|
MANUFACTURER'S NAME: |
Professional Coating Technologies, Inc. |
|
|
||||||
|
ADDRESS: |
1001 Mt. Lebanon, Cedar Hill, TX 75104 - Cedar Hill, TX 75104 |
||||||||
|
EMERGENCY 24 HR. TELEPHONE NUMBER: |
(972) 291-7474 |
|
|
|
|||||
|
OTHER INFORMATION CALLS: |
(972) 291-7474 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
SECTION 1 - IDENTIFY |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
TRADE NAME AND SYNONYMS: |
COS-50TM |
|
|
|
|
|
|||
|
C.A.S. NUMBER: |
None, Mixture |
|
|
|
|
|
|
||
|
CHEMICAL NAME: |
Water based Resin |
|
|
|
|
|
|
||
|
CHEMICAL FAMILY: |
Petroleum Hydrocarbon Resin |
|
|
|
|
|
|||
|
FORMULA: |
Variable Mixture |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SECTION 2 - HAZARDOUS INGREDIENTS |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
PRINCIPAL HAZARDOUS COMPONENTS: |
|
% |
|
THRESHOLD LIMIT VALUE |
|||||
|
(Chemical & Common Names) |
|
|
|
|
|
(Units) |
|
||
|
Petroleum Resin 008052-42-4 |
|
|
58 |
|
|
5.00 mg/m 3 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
SECTION 3 - OTHER INGREDIENTS |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
CHEMICAL |
COMMON NAMES |
|
(Units) |
|
THRESHOLD LIMIT VALUE |
||||
|
Asphaltine |
Petroleum 008052-42-4 |
|
60 |
|
5.00 mg/m 3 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
SECTION 4 - PHYSICAL & CHEMICAL CHARACTERISTICS |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
BOILING POINT: |
212° F |
|
SPECIFIC GRAVITY: |
(H20-1.00): .971 - 1.03 |
|
||||
|
VAPOR PRESSURE: (mmHG): N/D |
(mmHG): N/D |
|
VAPOR DENSITY: |
(Air @ 1): > 1 |
|
||||
|
PERCENT VOLATILE BY VOLUME: |
42 - 48 |
EVAP. RATE |
(H20 = 1.00): 1 |
|
|||||
|
APPEARANCE AND ODOR: |
Low viscosity, smooth brown liquid and slight petroleum odor |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
SECTION 5 - FIRE AND EXPLOSION |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
FLASH POINT: |
N/A in water Born state |
AUTO IGNITION TEMP: |
N/A |
|
|||||
|
FLAMMABLE LIMITS IN AIR % BY VOLUME: |
|
LOWER: |
N/A |
UPPER: |
N/A |
|
|||
|
EXTINGUISHER MEDIA: |
Non-flammable in water born state. *NOTE: in asphalt state: small fires use dry chemical, CO2, halon, water spray or standard foam. Large fires use water spray, fog or standard foam. |
||||||||
|
|
|
|
|||||||
|
|
|
(1987 Emergency Response Guidebook D.O.T. P5800.4 Guide No. 27) |
|
|
|||||
|
SPECIAL FIRE FIGHTING PROCEDURES: |
Non-flammable in emulsion state. |
|
|
||||||
|
NOTE: in asphalt state: |
|
Move vessel from fire area if you can do it without risk. Cool containers that |
|
||||||
|
are exposed to flames with water from the side until well after the fire is out. Stay away from ends of tank. For massive fire in cargo area, use unmanned hose holder or monitor nozzles. If this is impossible, withdraw from area and let fire burn. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tank due to fire. |
|||||||||
|
|
|
(1987 Emergency Response Guidebook D.O.T. P5800.4 Guide No. 27) |
|
|
|||||